Place of Origin : Zhejiang
Brand Name : Eberry
Model Number : ERM1L
Supply Ability : 10000 Unit/Units per Month
Price : $30.00 - $350.00/pieces
Certification : CE,CQC,ISO9001
MOQ : 300 pieces
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time : 5-10 days
Packaging Details : Carton
Product name : Moulded Case Circuit Breaker
Breaking Capacity : 12KA
Rated Voltage : AC400V
Rated Current : 16
Rated Frequency (Hz) : 50 Hz/60 Hz
Poles Number : 2/3/4
Protection : Overload and short circuit
Material : PC/ABS
Rated Frequency : 50 Hz/60 Hz
Customization : Yes
2P 800 Volt DC MCCB for Moulded Case Circuit Breaker Mini Circuit Breakers
| Model | ERM1L-125 | ERM1L-250 | ||||
| Current level of frame Inm(A) | 125 | 250 | ||||
| Rated current(A) | 16,20,25,32,40,50,63,80,100,125 | 100,125,140,160,180,200,225,250 | ||||
| Rated operational voltage Ue(V) | AC400V | |||||
| Rated insulation voltage Ui(V) | AC800V | |||||
| Number of poles | 3 | 4 | 3 | 4 | ||
| Level of rated limit short circuit breaking capacity | M | H | | M | H | |
| Rated residual action current I△n Type I | 100,300,500 mA | 100,300,500 mA | ||||
| Rated residual action current I△n Type II | 30,100,300 mA | 30,100,300 mA | ||||
| Rated residual non action current | I△n x 50% | |||||
| Rated resudual short circuit connecting(breaking) capacity I△n(mA) | Icu x 25% | |||||
| Rated limit short circuit breaking capacity Icu(kA) AC400V | 50 | 85 | 50 | 50 | 85 | 50 |
| Rated service short breaking capacity Ics(kA) AC400V | 35 | 50 | 35 | 35 | 50 | 35 |
| Operational performance(times) Power on | 3000 | 2500 | ||||
| Operational performance(times) Power off | 7000 | 6500 | ||||
| Flashover distance(mm) | <=50 | <=50 | ||||
| Model | ERM1L-400 | ERM1L-630 | ||||
| Current level of frame Inm(A) | 400 | 630 | ||||
| Rated current(A) | 200,225,250,315,350,400 | 400,500,630 | ||||
| Rated operational voltage Ue(V) | AC400V | |||||
| Rated insulation voltage Ui(V) | AC800V | |||||
| Number of poles | 3 | 4 | 3 | 4 | ||
| Level of rated limit short circuit breaking capacity | M | H | | M | H | |
| Rated residual action current I△n Type I | 100,300,500 mA | 100,300,500 mA | ||||
| Rated residual action current I△n Type II | 300,500,1000 mA | 300,500,1000 mA | ||||
| Rated residual non action current | I△n x 50% | |||||
| Rated resudual short circuit connecting(breaking) capacity I△n(mA) | Icu x 25% | |||||
| Rated limit short circuit breaking capacity Icu(kA) AC400V | 65 | 100 | 65 | 65 | 100 | 65 |
| Rated service short breaking capacity Ics(kA) AC400V | 42 | 65 | 42 | 42 | 65 | 42 |
| Operational performance(times) Power on | 1500 | 1500 | ||||
| Operational performance(times) Power off | 4000 | 4000 | ||||
| Flashover distance(mm) | <=100 | <=100 | ||||





|
|
2P 800 Volt DC MCCB Mini Molded Case Breakers 12KA Images |